| Category | Polymer , Film , Thermoset , Polyimide, TS , Polyimide, Thermoset Film | 
| Manufacturer | DuPont | 
| Trade Name | Kapton® | 
| Port | Ningbo port,China | 
| Trade Terms | FOB, CFR, CIF | 
| Payment Terms | L/C, T/T, Western Union | 
| Download PDF | DuPont™ Kapton® 300KN Polyimide Film, 75 Micron Thickness.pdf  | 
| Price | EMAIL US sales@lookpolymers.com | 
| Physical Properties | Metric | English | Comments | 
|---|---|---|---|
| Density | 1.45 g/cc | 0.0524 lb/in³ | |
| Water Absorption | 3.0 % | 3.0 % | 24 hr/23°C. ASTM D570 | 
| Mechanical Properties | Metric | English | Comments | 
|---|---|---|---|
| Film Elongation at Break, MD | 65 % | 65 % | Orientation not specified; ASTM D882 | 
| Poissons Ratio | 0.34 | 0.34 | Value for Kapton® HN | 
| Secant Modulus | 3.70 GPa | 537 ksi | ASTM D882 | 
| Coefficient of Friction, Dynamic | 0.48 | 0.48 | Value for Kapton® HN. Film to film. ASTM D1894-90 | 
| Coefficient of Friction, Static | 0.63 | 0.63 | Value for Kapton® HN. Film to film. ASTM D1894-90 | 
| Film Tensile Strength at Break, MD | 241 MPa | 35000 psi | Orientation not specified; ASTM D882 | 
| Thermal Properties | Metric | English | Comments | 
|---|---|---|---|
| Specific Heat Capacity | 1.09 J/g-°C | 0.261 BTU/lb-°F | Value for Kapton® HN | 
| Thermal Conductivity | 0.120 W/m-K | 0.833 BTU-in/hr-ft²-°F | Value for Kapton® HN | 
| Maximum Service Temperature, Air | 400 °C | 752 °F | Kapton® can function after brief exposure to 400°C (750°F). Various grades are UL rated for continuous service at 220-240°C (430-460°F). | 
| Minimum Service Temperature, Air | -269 °C | -452 °F | Maintains properties and flexibility | 
| Glass Transition Temp, Tg | 385 °C | 725 °F | Value for Kapton® HN | 
| Flammability, UL94 | V-0 | V-0 | 
| Optical Properties | Metric | English | Comments | 
|---|---|---|---|
| Refractive Index | 1.70 @Wavelength 589.3 nm | 1.70 @Wavelength 589.3 nm | Value for Kapton® HN. Na D line; ASTM D542-90 | 
| Electrical Properties | Metric | English | Comments | 
|---|---|---|---|
| Electrical Resistivity | 1.00e+10 ohm-cm | 1.00e+10 ohm-cm | Kapton® HN in damp heat; IPC-TM-650; Method 2.5.17 | 
| 1.00e+17 ohm-cm | 1.00e+17 ohm-cm | per ASTM D257-91 for Kapton® HN | |
| Dielectric Constant | 3.6 @Frequency 1000 Hz | 3.6 @Frequency 1000 Hz | Use evaporated metal electrodes, two terminal system of measurement at standard conditions.; ASTM D150 | 
| Dielectric Strength | 197 kV/mm | 5000 kV/in | Flat sheets in air placed between 1/4 in diameter brass electrodes with 0.8 mm (1/32 in) edge radius subjected to 60 cycles AC voltage at 600V/s rate of rise to the breakdown voltage.; ASTM D149-81 | 
| Dissipation Factor | 0.0020 @Frequency 1000 Hz | 0.0020 @Frequency 1000 Hz | Same test as dielectric constant. |